cms 500dl manual

Health Connector LLC owns and reserves all of the rights comprised in the copyright of this document. No part of this document may be changed, excerpted, copied, reproduced, or imitated in any form or by any means without prior written consent of Health Connector LLC. By listening intently and applying some of the changes as measurement using the carbon-monoxide-blood-gas analyzer suggested by our customers, we hope you will find that the CMS 5.2.2.3 Characteristics of Population under Clinical Research. Avoid 2) Avoid making any body movement, especially your finger while moving the oximeter from a cold to a hot and humid taking measurement.Symbol Meaning The screen 1. If the Oximeter 1. This is normal. turns off does not detect Just turn on the BF-type application part suddenly.Oxygen The Oximeter 1. The finger is not 1. Make sure that saturation is defined as the ratio of oxyhemoglobin (HbO ) to the total fails to display placed between the finger is. The relative absorption of light by oxyhemoglobin (HbO) and deoxyhemoglobin is Chapter 4 Maintenance and Troubleshooting then calculated according to the Beer-Lambert's law and a Maintenance quantitative measurement of the users’. Spot check pulse oximeter takes 1-2 readings every second and takes an average of 4-6 readings before displaying the result. Hence, you will have to wait at least 4-6 seconds before a result will be displayed Attention: Do not immerse any part of the instrument into on the monitor. Keep your body as still as possible. Once the reading stabilizes, read the Power-on key measured values of the oxygen saturation level and pulse rate on the LED screen. Operation Steps 2.8.1 Installing the Batteries Install the two AAA dry batteries into the battery slot according to the indicated polarity and mount the battery. Put the silicon cover back on. Ensure that the batteries are installed with correct polarities to avoid damage to the instrument. 2.8.

3 Switching On the Power Supply of the Pulse Oximeter Insert one finger completely into the silicon padded finger chamber of the Oximeter. Currently, we are shipping within 7-14 business days from the date of purchase.For example: The pulse oximeter can now detect SpO2 levels up to 100%. Its small size makes it easy to carry around and a lanyard is also included for added convenience. Terms and conditions apply. We will actively and aggressively pursue \u003cspan\u003eany parties who infringe on our intellectual property rights to the maximum extent allowed by the law. Warm your hands and fingers before taking your measurements by rubbing your hands together. Remember your pulse oximeter is measuring your SpO2 and PR based on your blood flow. Some people though may require a longer time for the pulse oximeter to optimize its sensitivity. However, there are certain conditions where this may not apply. While you can still use it at high elevation, you will need to know the normal range of your SpO2 at that elevation. Every individual is different and your doctor would be in the best position to provide the most accurate answer to this question. It will give you a reading as long as you have your finger inside the finger chamber. Once you take your finger out, the pulse oximeter will turn off after 10 seconds. We have also upgraded many internal hardware and software components of the pulse oximeter. For example: The pulse oximeter can now detect SpO2 levels up to 100%. Once you take your finger out, the pulse oximeter will turn off after 10 seconds.Please try again. We have also upgraded many internal hardware and software components of the pulse oximeter. Taking a reading is easy, just clip it onto your finger and turn it on at the press of a button. Its small size makes it easy to carry around and a lanyard is also included for added convenience. Comes with 2 AAA batteries and a silicon cover to protect your pulse oximeter from dirt and damage.

Terms and conditions apply. Please refer to the manufacturer website for more info. We will actively and aggressively pursue any parties who infringe on our intellectual property rights to the maximum extent allowed by the law. Beware of Imitation, Buy Original. If the link does not open properly on your desktop or mobile device, please contact us. Warm your hands and fingers before taking your measurements by rubbing your hands together. If the blood flow in your finger drops below a certain level, the pulse oximeter will not be able to function. Some people though may require a longer time for the pulse oximeter to optimize its sensitivity. You may have to wait about 30 seconds for the readings to stabilize. If possible, switch to an unpolished nail or consider another application site. We suggest that you consult a physician before use. It does not measure blood pressure. We do not suggest that you use rechargeable batteries because some may not work with the device. It does not record data. In fact the hypoallergenic finger chamber is made of medical grade silicone. However, there are certain conditions where this may not apply. Your doctor will be in the best position to advice where your readings should be. If you are in the middle of exercising, we advise to take readings during resting phases while the body is not mobile. You may want to check with your physician who will be in a better position to advice on what to look out for especially if you have a medical condition like a-fib. While you can still use it at high elevation, you will need to know the normal range of your SpO2 at that elevation. For this reason, we advise to consult your physician. It will give you a reading as long as you have your finger inside the finger chamber. Since it does not record data it is not meant to be used overnight or during sleep. Please consult with your vet who will be able to suggest a more suitable device for animals.

We have also upgraded many internal hardware and software components of the pulse oximeter. Since it does not record data it is not meant to be used overnight or during sleep. Please consult with your vet who will be able to suggest a more suitable device for animals. Its small size and lanyard makes it convenient and easy to carry around.Finger chamber features a SMART Spring System that accomodates a wide range of finger sizes. Works for ages 12 and above.Readings now faces instead of away from the user for easy read.We have also upgraded many internal hardware and software components of the pulse oximeter. Since it does not record data it is not meant to be used overnight or during sleep. Please consult with your vet who will be able to suggest a more suitable device for animals. Your input is very much appreciated. Share it with your friends so they can enjoy it too. Facebook Twitter Be the first to review this item With Covid, even more so. It provides an accurate reading in a short time. I would buy it again! I have been looking for a pulse monitor that's portable and easy to use and this fits the bill. I tried a Fitbit but that wasn't accurate, and I didn't want to strap an exercise monitor around my chest, but this is perfect. I can put the lanyard around my neck when I'm out for a hike and then make a quick stop to check my pulse. I also use it when I'm on my excersie bike so I can hit my target heart rate. Like others have commented, I get the quickest and most accurate reading when my hand is still and I'm not putting down pressure on the unit with my finger. I checked the accuracy against the medical equipment in my doctors office during my last appointment and it is right on. And with the pandemic raging across the country it's gives me peace of mind that my O2 levels are OK since I'm part of a vulnerable group for serious Covid-19 complications.Works well, I took it to work and compared with expensive one, same reading.

It is a little slow to get reading but for the money excellentIt is quick and very easy to use. It is a great value also. It gives the fastest reading when sitting; moving around delays the readings a bit. The pulse oximeter works, the numbers are easy to read, it appears to be accurate. I like the protective silicone cover, the lanyard, and that it takes AAA batteries, which are included but easy to replace if needed. It was difficult to choose out of many brands and prices. I am satisfied with my choice. They are well reviewed and clearly superior. It appears to be a little opportunism has entered the medical supply business during the pandemic. Sad as that may be, I will have little choice but to pay the higher price when the product becomes available. For me, the oximeter is totally useless ??? We encourage all our present and future customers to contact us via phone or email about anything you deem suitable. Please visit our contact page to view our contact information. User Manual Health Connector LLC owns and reserves all of the rights comprised in the copyright of this document. The information in this document is subject to change without notice. Health Connector LLC reserves the right of final interpretation of this document.If the functional tester can measure the portion of overall errors of the mainframe-probe system of the Oximeter attributable to the mainframe of the Oximeter, the functional tester can test the accuracy of a pulse Oximeter that duplicates the calibration curve. Note: The product does not provide the alarm function and is not suitable for continuous long-term monitoring. By listening intently and applying some of the changes as suggested by our customers, we hope you will find that the CMS 500DL is a much more user-friendly, reliable and comfortable pulse oximeter than its predecessor. Before using this product, please read the user manual carefully and follow the instructions stated herein.

Please also check that all accessories are complete as listed in the packing list and whether any component is damaged during shipping. Note: The functional tester shall not be used to evaluate the accuracy of the probe of the pulse Oximeter or the accuracy of the pulse oxygen monitor Note: The pulse Oximeter has a specific calibration curve, and is 30 5 measured values of a carbon-monoxide-blood-gas analyzer Determination of Oxygen Saturation Accuracy The claimed oxygen saturation is supported by coverage of the entire range of clinical research measurements Data Collection In the clinical test process, data points are recorded with comparable density in the entire claimed range Data Analysis For each claimed range, the oxygen saturation accuracy of the pulse Oximeter should be represented in the form of mean root square of the difference between the measured values of oxygen saturation and the reference value. Only certified engineers should maintain and repair it. Change the contact position between the Oximeter probe and the finger periodically if you are monitoring your SpO2 level and pulse rate for more than 2 hours. Stop immediately if you have broken skin or the blood circulation of your finger is affected during prolonged use. This product is not designed to be used by newborn babies. Seek medical care if the measured value goes beyond the normal range and you are sure that the instrument is not 2 6 malfunctioning. The pulse oximeter uses infrared light (invisible to your eyes) to measure your SpO2 level. People who need SpO2 and pulse rate measurements because of a medical condition should not use the CMS 500DL and should consult with their physician. For details about clinical limitations and contraindications, please refer to relevant medical literatures. Note: The oxygen saturation accuracy is a root mean square of the difference. The measured values of the instrument are distributed according to statistical probability.

Hence, please avoid direct exposure to strong light (such as beams from operating lamps or sunlight) during measurement. The probe of the Oximeter is placed on the same arm that a blood pressure cuff arterial duct or intravenous injection is placed. The user suffers from hypotension, severe vascular atrophy, severe anemia, or low oxygen. The user is in sudden cardiac arrest or shock state. The user is wearing nail polish or artificial nails. 6. Technical parameters Parameter Oxygen Display range saturation Pulse rate Value 35% to 100% 25 bpm to 250 bpm 1.2 Warnings Warning: Do not use the Oximeter in an environment with any flammable gases, flammable anesthetic, or other flammable substances. 27 4 8 Warning: Keep unit and lanyard away from children as the included lanyard may pose as an entanglement or choking hazard to small children. Adult supervision required; never leave children unattended with unit or lanyard Warning: Do not throw the batteries into fire, as that may cause an explosion. Warning: Do not attempt to charge the included batteries, as that could cause leakage, fire disaster, or even explosion. Dispose the used batteries in accordance to the local laws and regulations. Working Current 5. Normal working condition 35 ma 5 26 9 2) Avoid making any body movement, especially your finger while taking measurement. 3) Long fingernails obstruct the light sensor and prevent accurate measurement. Please keep fingernails short while using the instrument. 4) Excessive ambient infra-red light, especially in an overly bright lit room, can interfere with the sensor, preventing an accurate measurement. 5) Poor blood circulation can affect oximeter readings. Warm your hands and fingers before taking measurements. Note that the pulse oximeter is measuring your SpO2 and PR based on your blood flow. If the blood flow is too low, the pulse oximeter will not be able to get a reading.

6) Some people with medical conditions such as anemia, hypotension and hypothermia may experience an inaccurate reading during use. In such case, we suggest that you consult a physician. Caution: Do not operate the Oximeter if it is wet. Avoid moving the oximeter from a cold to a hot and humid environment. Caution: Install the batteries properly before powering on the Oximeter for normal use. Please remove the batteries if you are not planning to use the Oximeter for an extended period of time. Caution: Close the battery cover when the instrument is in use. 25 6 10 1.3 Symbol Symbol Meaning Problems Possible Cause Solution damaged. 3. Contact the distributor. %SpO2 BF-type application part Caution: Please see this manual. Symbol Warning Meaning Temperature limitation When end users abandon this product, they must send the product to the collection place for recycling. Information about possible harm of this product to users if not used properly. Caution Attention Important information on proper usage of the device. Necessary information to protect this product against damage 23 8 12 Chapter Overview About This Product SpO2 stands for peripheral capillary oxygen saturation. It is an important physiological parameter involved in respiration and circulation. The Pulse Oximeter feature herein is small, portable, non-invasive and easy to use. A pulse oximeter works by passing a beam of red and infrared light through a pulsating capillary bed and then measure the amount of red and infrared light emerging from the tissues via a sensor. Replace the batteries if they are low on power. Clean the Oximeter and the fingertip before every use to ensure accurate reading. Periodically check the Oximeter for damage.The relative absorption of light by oxyhemoglobin (HbO) and deoxyhemoglobin is then calculated according to the Beer-Lambert's law and a quantitative measurement of the users oxyhemoglobin status i.e. Oxygen saturation level (SpO2) is derived.

Do not use for continuous monitoring. 2.3 Product Features Lightweight, portable and easy to use Huge LED screen for easy reading Low Battery indicator Automatic shut down if no signal is detected after 16 seconds. The device is equipped with two 1.5 V AAA batteries, which will allow the pulse oximeter to operate for approximately 30 hours 14 2.4 Limitations Spot check pulse oximeter takes 1-2 readings every second and takes an average of 4-6 readings before displaying the result. Hence, you will have to wait at least 4-6 seconds before a result will be displayed on the monitor. If the pulse oximeter fails to detect blood flow for the first few seconds, the results will be delayed accordingly. The pulse oximeter does not work for people with naturally small fingers or low peripheral blood flow. This is because the pulse oximeter could not detect enough blood for a measurement. Please note that prolonged use of a pulse oximeter, hypotension, vasoconstriction, hypothermia and certain medications can lead to low or restricted blood flow. Nail polish can also impede the pulse oximeter from taking a reading. To know how much blood flow is being detected by the pulse oximeter, you will need a model that can display the plethysmograph (CMS 500D). Finally, it is generally accepted that the saturation percentage is unreliable on the steep part (around 60 mm Hg) of the oxyhemoglobin dissociation curve. 2.5 Innovative features of the CMS 500DL The CMS 500DL is designed to address and alleviate some of the above problems by 11 during cleaning. Attention: Do not immerse any part of the instrument into any liquid. 3.2 Disinfection Before using the instrument, wipe the silicon finger chamber using a piece of dry soft cloth slightly moistened with isopropyl alcohol. Clean finger with alcohol before and after every use. Clean the outer surface of the instrument (including the LED screen) using a piece of dry soft cloth slightly moistened with isopropyl alcohol.

Do not immerse the unit in alcohol. Caution: Do not rub the body of the instrument using materials such as steel wire balls or polished metal objects. Caution: Ensure that there is no cleaning solution on the surface of the instrument. Attention: Do not allow any liquid to flow into the instrument 19 12 16 Product Structure and Operation Steps 2.6 Schematic Structural Diagram LED screen Power-on key Shaft housing Battery cover hypoallergenic Reading Oxygen Saturation level and Pulse Rate from the LED Screen Do not move your finger during measurement. Keep your body as still as possible. Once the reading stabilizes, read the measured values of the oxygen saturation level and pulse rate on the LED screen Switching Off the Power Supply of the Pulse Oximeter The Oximeter will automatically shut down in 16 seconds after finger is removed from the chamber or if no signal is detected by the device About the Display The instrument uses an LED screen with unidirectional display. Note: Replace the batteries when the symbol flickers continuously on the LED screen. This means that the batteries are low. If the symbol flickers only once, it is not indicative of low-voltage 17 If you do not insert your finger completely into the chamber, measurement will be inaccurate. 2.7 Schematic Diagram of Display The following figure shows the information display on the LED screen of the Oximeter in normal detection state: Note: Before each use, clean finger and the silicon padded finger chamber with isopropyl alcohol. The silicon is non-toxic, soft and Operation Steps Installing the Batteries Install the two AAA dry batteries into the battery slot according to the indicated polarity and mount the battery cover by sliding the cover in place until you hear a click sound. 14 18 Ensure that the batteries are installed with correct polarities to lanyard through the thin end of the lanyard, and tighten the lanyard. Put the silicon cover back on.

Thread the thin end of the lanyard through the lanyard hole, thread the coarse end of the Switching On the Power Supply of the Pulse Oximeter Insert one finger completely into the silicon padded finger chamber of the Oximeter. The fingernail should be facing the top chamber (which contains the sensor). Press the power key to turn on the Pulse Oximeter. 16 Failure to follow these instructions may cause measuring abnormality Directions for use We re proud of the care and quality English Spanish Limited Five-Year Warranty Your Ear Thermometer is Failure to follow the safety rules and other basic safety precautions English French Portuguese Spanish Limited Five-Year Warranty Your Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual Congratulations on the purchase of your OWNER S MANUAL Read these instructions before use.This Infrared thermometer Safety Operation Maintenance Due to continuing improvements, actual product may differ slightly from This Infrared thermometer measures and displays non-contact Thermometer IMPORTANT.Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. OWNER S MANUAL Read these instructions before use.By purchasing All rights reserved. No part of this publication may be reproduced or transmitted OWNER S MANUAL Read these instructions before use.The Model 42515 IR thermometer Slide off the battery compartment cover on the back of the This charger and tester is included in a series of professional chargers from CTEK Sweden AB and Quick Guider After getting this alarm system, you need to do the following Instruction Manual Read this operation manual The EZ40 detects the presence of combustible Our company may also seek to maintain this FAA 500 TR P Trim Ring transparent with Color Inserts.If there are any questions, or requests, please do not hesitate to contact the dealer.

This manual applies to the MicroView Please read this instruction UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall If shipping This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging This Infrared thermometer measures and displays non-contact Instructions for Using the LaserTouchOne Charging the Unit. 5 Holding the Device. 5 Treatment Steps. This manual contains important safety and operating information in order to prevent accidents. Please read this manual thoroughly The Green Dot is designed as the primary targeting Prepared by Checked by Approved by 1.Use only specified peripheral equipment and interface cables or you may experience problems. When IMPORTANT SAFEGUARDS SAVE AND READ THESE INSTRUCTIONS When Operating Instructions Comfortable Behind the Neck design INDEX Page USE. 3 WARRANTY. 3 FOR SAFE USE. 4 BEFORE USE THE DETECTOR. Model CPA12KH AIR CONDITIONER Please read this instructions carefully. 1.GENERAL OPERATING INSTRUCTIONS Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements. Retain this Owner s Manual for future reference.To use this website, you must agree to our Privacy Policy, including cookie policy. Finger Pulse Oximeter. User Manual CMS Mobility Inc owns and reserves all of the rights comprised in the copyright of this document. CMS Mobility Inc reserves the right of final interpretation of this document.Note: The product does not provide the alarm function and is not suitable for continuous long-term monitoring.

By listening to our customers and applying some simple technological innovations, you will come to see that the CMS 500DL is one of the most user-friendly, reliable and comfortable pulse oximeters that you will ever come to own. Before using this product, please carefully read the manual and follow the instructions stated herein. Check whether all accessories are complete against the packing list and whether any component is damaged during shipping. Note: The functional tester shall not be used to evaluate the accuracy of the probe of the pulse Oximeter or the accuracy of the pulse oxygen monitor Note: The pulse Oximeter has a specific calibration curve, and is precise for the combination of the mainframe and probe of the pulse Oximeter. If the functional tester can 30 5 The claimed oxygen saturation is supported by coverage of the entire range of clinical research measurements Data Collection In the clinical test process, data points are recorded with comparable density in the entire claimed range Data Analysis For each claimed range, the oxygen saturation accuracy of the pulse Oximeter should be represented in the form of mean root square of the difference between the measured values of oxygen saturation and the reference value. Change the contact position between the Oximeter probe and the finger periodically if you are monitoring your SpO2 levels and pulse rate for more than 2 hours. Stop immediately if you have broken skin or the blood circulation of your finger is affected during prolong use. The pulse oximeter uses infrared light (invisible to your 2 6 eyes) to measure your SpO2 levels. This device is not intended to diagnose or treat any medical condition or disease. The following factors may affect the accuracy of the measurement: The Oximeter is used in an environment involving high-frequency devices, such as high-frequency electric knives and CT apparatuses. Ambient light intensity is too bright. The user is wearing nail polish or artificial nails.

Parameter Oxygen Display range saturation Pulse rate Oxygen saturation Resolution Pulse rate Value 35% to 100% 25 bpm to 250 bpm 1% 1 bpm 1.2 Warnings Warning: Do not use the Oximeter in an environment with any flammable gases, flammable anesthetic, or other flammable substances. 27 4 8 Warning: Keep unit and lanyard away from children as the included lanyard may present an entanglement or choking hazard to small children. Dispose the used batteries in accordance to the local laws and regulations of your region. Internal Power Supply Working Current 5. Normal working condition Two 1.5 V dry batteries 35 ma Warning: Do not use the Oximeter in an MRI or CT environment. Working Temperature 5 C to 40 C (41 F to 104 F) 5 26 9 3) If your fingernails are too long, this may obstruct the sensor from the LED lights. Please make sure that your fingernails are kept short. 4) Excessive ambient infra-red light, especially for people who use the pulse oximeter in an overly bright lit room can interfere with the sensor. 5) Poor circulation can affect oximeter readings. Warm your hands and fingers before taking your measurements. If the blood flow in your finger drops below a certain level, the pulse oximeter will not be able to function. 6) Some people with medical conditions such as anemia, hypotension and hypothermia can experience an inaccurate reading during use. If that may be the case for you, we suggest that you consult a physician. Please remove the batteries if you are not planning to use the Oximeter for a long time. Caution: Close the battery cover when the instrument is in use. Chapter 5 Technical Description and Safety Type 5.1 Technical Specifications 1. Dimensions: 58.0 mm (Width) 32.0 mm (Depth) 33.2 mm 25 6 10 1.3 Symbol Problems Possible Cause Solution Symbol Meaning BF-type application part Caution: Please see this manual. The Oximeter cannot be powered on. 1. The finger is not placed properly between the sensor and the LED. 2.

The user is moving his finger or body. 1. The batteries are empty, or are not installed at all. 2. The batteries are incorrectly installed. 3. The Oximeter is damaged Place the finger at the correct position. 2. Ensure that the user's body is stationary. 1. Replace the batteries. 2. Correctly install the batteries according to the polarity indication. 3. Contact the distributor. Symbol Warning Caution Attention Meaning Temperature limitation When end users abandon this product, they must send the product to the collection place for recycling. Information that you must learn about possible harm of this product to users Some important information that you must learn Information that is necessary for you to protect this product against damage 8 12 Chapter Overview About This Product SpO2 stands for peripheral capillary oxygen saturation. Clean the Oximeter and the fingertip before use to ensure accurate reading. Remove the batteries from the battery slot and properly store them if you do not plan to use the Oximeter for a long period of time. Periodically check the Oximeter for damage. Avoid using the Oximeter in an environment with inflammable gases or using it in an environment where the temperature or humidity is excessively high or low. Check the accuracy of the oxygen saturation and pulse rate readings by using an appropriate calibration apparatus. 21 accuracy, the CMS 500DL uses a proprietary algorithm to collect data from pulsatile arterial blood and ignores local noise from the tissues. The relative absorption of light by oxyhemoglobin (HbO) and deoxyhemoglobin is then processed according to the Beer-Lambert's law and a qualitative measurement of the users oxyhemoglobin status i.e. Oxygen saturation level (SpO2) derived. Due to the sensitivity of the pulse oximeter, you should keep your finger stationary during measurement. It is recommended that you use this instrument for measurement before or after sports. Do not use for continuous monitoring. 2.